Ivan V. Viktorov, Vladimir M. Nikitin
DOI: 10.47026/1810-1909-2021-1-36-46
Key words
frequency converter, synchronous machine, load angle, vector diagram, motor power factor, electromagnetic torque, overload capability, dynamic stability.
Annotation
The article considers a method of economical speed control of synchronous motor with permanent magnet excitation using autonomous voltage inverter. The method provides stable (without tilting) rotation of the rotor without using the rotor position sensor signals. An algorithm, which realizes minimal losses in the machine and in the inverter, is proposed.
The assumption of insignificant influence of voltage drop in stator winding active resistance on processes in synchronous machine accepted in the analysis is confirmed by parameters of real motors from 7DVM series and results of the experiment. It is shown that the mode with cosφ = 1 differs little from the generally accepted mode with load angle θ = φ. The results of experimental verification of the method in electric drive with 7DVM250 motor of 150 kW power are presented, which showed high dynamic stability of the system in a wide range of speeds and loads and while maintaining the most economical energy exchange between the motor and inverter (that is with cosφ = 1).
References
Information about the authors
Ivan V. Viktorov – 1st Category Software Engineer, Department of Electric Drive and Converting Equipment, ChEAZ JSC, Russia, Cheboksary (cheaz@cheaz.ru).
Vladimir M. Nikitin – Candidate of Technical Sciences, Deputy Head of the Department of Electric Drive and Converting Equipment, ChEAZ JSC, Russia, Cheboksary (cheaz@cheaz.ru).
For citations
Viktorov I.V., Nikitin V.M. A METHOD OF ECONOMICAL CONTROL OF A SYNCHRONOUS MOTOR WITHOUT A ROTOR POSITION SENSOR. Vestnik Chuvashskogo universiteta, 2021, no. 1, pp. 36–46. DOI: 10.47026/1810-1909-2021-1-36-46 (in Russian).