Главная  /  Наука и инновации  /  Вестник Чувашского университета  /  Metadata for the articles  /  Vestnik Chuvashskogo universiteta, 2022, no. 3. Topic of this Issue: Electrical Technology and Power Engineering  /  ANALYSIS OF EXISTING APPROACHES AND METHODS OF DIAGNOSTICS OF ON-LOAD TAP CHANGER OF POWER TRANSFORMERS

ANALYSIS OF EXISTING APPROACHES AND METHODS OF DIAGNOSTICS OF ON-LOAD TAP CHANGER OF POWER TRANSFORMERS

DOI: 10.47026/1810-1909-2022-3-61-72

УДК 621.314

ББК 31.264-08

Georgi M. MIKHEEV, Anton A. DIMITRIEV, Huseyjon U. KALANDAROV, Oleg V. FEDOROV

Key words

power transformers, switching devices, on-load tap changer, contactor contacts, multichannel digital oscilloscope, diagnostics, transformer oil, operating staff

Abstract

In electrical networks of almost all voltage classes, the main link in the work on the transmission of electrical energy is a power transformer. At the moment, about 60% of them are operated in our country with a significant excess of service life, which increases the requirements for their technical control and diagnostics of all units. Switching devices are an integral part of power transformers. They are necessary to regulate voltage on substation busbars depending on the load of consumers. Not only the reliability of power supply of industrial enterprises, cities and agriculture, but also the quality of electrical energy depends on their operation. At the same time, they are one of the vulnerable nodes of voltage converters. Although the parameters of diagnostic signs for switching devices are not as extensive as the power transformer itself, they nevertheless require special attention from the operating personnel. This is due not only to the variety of switchgear types that exist, but also to the methods used to diagnose them. For this reason in this work an attempt has been made to analyze the existing approaches and methods of diagnosing these mechanical controlled voltage regulators. We propose a new approach in terms of diagnostics of high-voltage equipment, including power transformers – introdiagnostics. It is based on methods of non-destructive (without opening tanks and draining dielectric liquids) control of parameters that characterize the state of electrical equipment. We present an original method of diagnosing the on-load tap changer, based on oscillography and subsequent analysis of operation of the on-load tap changer contact system without draining transformer oil from the diverter switch’s tank.

References

  1. Koltmen D.U. Transformator [Transformer]. Moscow, V mire nauki Publ, 1988, 76 p.
  2. Metodicheskie ukazaniya po naladke ustroistv pereklyucheniya otvetvlenii obmotok pod nagruzkoi (proizvodstva NRB i GDR) transformatorov RPN [Guidelines for adjusting the tap changers for on-load tap changers (manufactured by the German Democratic Republic and the Republic of Bulgaria)]. Moscow., Soyuztekhenergo Publ., 1981, 44 p.
  3. Mikheev G.M. Diagnostirovanie pereklyuchayushchego ustroistva transformatora [Diagnosing of transformer switching device]. Elektricheskie stantsii, 2016, no.1(1014), pp. 50–56.
  4. Mikheev G.M. Diagnostika sostoyaniya kontaktnykh sistem RPN silovykh transformatorov putem tsifrovogo ostsillografirovaniya [Diagnostics of the contact systems of the on-load tap changers of power transformers by digital oscillography]. Promyshlennaya energetika, 2006, no. 3, pp. 20–22.
  5. Mikheev G.M. Metodika tsifrovogo ostsillografirovaniya protsessa pereklyucheniya kontaktov RPN tipa RNOA-110/1000 [Technique of a digital oscillograph of the contact change-over process of the tap changer of RNOA-110/1000 type]. Promyshlennaya energetika, 2007, no.3, pp. 8–11.
  6. Mikheev G.M. Elektrostantsii i elektricheskie seti. Diagnostika i kontrol’ elektrooborudovaniya [Power plants and electrical networks. Diagnosis and control of electrical equipment]. Moscow, Dodeka-XXI/DMK Press Publ., 2010, 297 p.
  7. Mikheev G.M., Kalandarov Kh.U., Ivanova T.G., Turdiev Kh.U. Sposob snyatiya ostsillogramm tokov trekhfaznogo regulyatora napryazheniya pod nagruzkoi, ustanovlennogo na obmotke vysshego napryazheniya silovogo transformatora, sobrannoi po skheme treugol’nik i ustroistvo dlya ego osushchestvleniya [Method for taking oscillograms of currents of three-phase voltage regulator under load, installed on the highest voltage winding of power transformer, assembled in delta circuit and device for its implementation]. Patent RF, no. 2643925, 2018.
  8. Mikheev G.M., Shevtsov V.M., Batalygin S.N. Sposob opredeleniya induktivnosti rasseyaniya trekhfaznoi vysokovol’tnoi obmotki silovogo transformatora [Method for taking oscillograms of currents of three-phase voltage regulator under load, installed on the highest voltage winding of power transformer, assembled in delta circuit and device for its implementation]. Patent RF, no. 2377586, 2009.
  9. Tursunov D.A., Ismoilov I.K. Analiz voprosov primenenie ustroistv regulirovanie silovykh transformatorov [Analysis of the application of devices regulating power transformers]. Universum: tekhnicheskie nauki, 2020, no. 8-3(77), pp. 8–11.
  10. Khismatullin A.S. Metodika tekhnicheskogo obsluzhivaniya i remonta promyshlennykh silovykh transformatorov po tekhnicheskomu sostoyaniyu [Methodology of maintenance and repair of industrial power transformers by technical condition]. Fundamental’nye issledovaniya, 2016, no. 2, pp. 308–313.
  11. Shirokov O.G., Medvedev K.M., Prokhorchik M.A. Struktura avtomaticheskoi sistemy tekhnicheskogo diagnostirovaniya ustroistva RPN silovogo transformatora [Structure of automatic system of technical diagnostics of tap changer of power transformer]. Vestnik Gomel’skogo gosudarstvennogo tekhnicheskogo universiteta im. P.O. Sukhogo, 2012, no. 2(49), pp. 1–8.
  12. Yakobson I.Ya. Ispytaniya pereklyuchayushchikh ustroistv silovykh transformatorov [Esting Switching Devices of Power Transformers]. Moscow, Energiya Publ., 1970, 56 p.
  13. Yakobson I.Ya. Naladka bystrodeistvuyushchikh pereklyuchayushchikh ustroistv silovykh transformatorov [Adjustment of quick acting switching devices of power transformers Moscow, Energiya Publ., 1976, 96 p.
  14. Yakobson I.Ya. Naladka i ekspluatatsiya pereklyuchayushchikh ustroistv silovykh transformatorov [Adjustment and exploitation of switching devices of power transformers]. Moscow, Energoatomizdat Publ., 1985, 120 p.
  15. Cincar N., Milojevic G. On-Load Tap Changer Testing Methods. Sweden, DV Power Publ, 2014, 150 p.
  16. C Rep. 411 VEB Transformatorenwerk “Karl Liebknecht” (TRO) (Bestand). Available at: https://www.archivportal-d.de/item/UVM2VHVWXWNSEHMLN7D7JX4CMKQQEN2A.

Information about the authors

Georgi M. Mikheev – Doctor of Technical Sciences, Professor, Department of Power Supply and Intellectual Electric Power Systems named after A.A. Fedorov, Chuvash State University, Russia, Cheboksary (mikheevg@rambler.ru; ORCID: https://orcid.org/0000-0003-2208-9723).

Anton A. Dimitriev – Post-Graduate Student, Department of Power Supply and Intellectual Electric Power Systems named after A.A. Fedorov, Chuvash State University, Russia, Cheboksary (Meterling21@mail.ru).

Huseyjon U. Kalandarov – Candidate of Technical Sciences, Acting Associate Professor, Department of Power Supply and Automation, Khujand Polytechnic Institute of the Tajik Technical University named after Academician M.S. Osimi, Tajikistan, Khujand (huseinjon.86@mail.ru; ORCID: https://orcid.org/0000-0002-4137-3538).

Oleg V. Fedorov – Doctor of Technical Sciences, Professor of Innovation Management Department, Nizhny Novgorod State Technical University named after R.E. Alekseev, Russia, Nizhny Novgorod (fov52@mail.ru; ORCID: https://orcid.org/0000-0001-5268-6399).

For citations

Mikheev G.M., Dimitriev A.A., Kalandarov H.U., Fedorov O.V. ANALYSIS OF EXISTING APPROACHES AND METHODS OF DIAGNOSTICS OF ON-LOAD TAP CHANGER OF POWER TRANSFORMERS. Vestnik Chuvashskogo universiteta, 2022, no. 3, pp. 61–72. DOI: 10.47026/1810-1909-2022-3-61-72 (in Russian).